Quality Management System Program of in Vitro/in Vivo Test Facility of Boron Neutron Capture Therapy at Kartini Research Reactor
Keywords:
n vitro / in vivo test facility, neutron flux, radiation shielding
Abstract
The quality manajement system program of in vitro / in vivo test facility of Boron Neutron Capture Therapy (BNCT) methode as quality assurance requirement for utilization of radial pearcing beamport of Kartini research have been done. Identification and management of technical specification and parameters meassurement of to the radial piercing beamport have been determined for preparing in vitro / in vivo test facility. The parameters are epithermal neutron flux is 9,8243E+05 n cm-2 s-1and thermal neutron flux is 3,0691E+06 n cm-2 s-1, radiation shielding of parafin, dimension and size of piercing radial and instrumentatin and control system for automatic transfer of in vitro / in vivo samplels have been documented. Management system of the documents for fullfil basic guidance to perform working job of in vitro / in vivo at the piercing radial beamport of Kartini Research Reactor in order purpose utilization of the reactor for safety worker of the radiation area, society and invironment beeing safelyDownloads
Download data is not yet available.
References
Analisis Pengembangan Fasilitas Uji In Vitro/In Vivo Metode Boron Neutron Capture Cancer Therapy Dengan Memanfaatkan Potensi Neutron Beamport Untuk Pendayagunaan Reaktor Triga Kartini, Widarto* , I sman Mulyadi T*, Puradwi IW*, Tri Nugroho HS*
Management System for Facilities and Activities, GS-R-3, IAEA, 2006
Application of The Management System for Facilities and Activities, IAEA Safety Standart Series, GS-G-3-1, IAEA, 2006
Quality Assurance Standards: Comparison Between IAEA 50-C/SG-Q AND ISO 9001:1994, IAEA-TECDOC-1182 ISSN 1011–4289, VIENNA, 2000,
Program Jaminan Mutu Operasi dan Perawatan Reaktor Kartini, Dok. No. PJM OPRK/APB-04, 2012.
Peraturan Kepala BAPETEN No.4 Tahun 2013 Tentang Proteksi Radiasi dan Keselamatan Radiasi Dalam Pemnafaatan Tenaga Nuklir.
Perka Kepala BAPETEN No. 4 Tahun 2010 Tentang Sistem Manajemen Fasilias dan Aktivitas.
Management System for Facilities and Activities, GS-R-3, IAEA, 2006
Application of The Management System for Facilities and Activities, IAEA Safety Standart Series, GS-G-3-1, IAEA, 2006
Quality Assurance Standards: Comparison Between IAEA 50-C/SG-Q AND ISO 9001:1994, IAEA-TECDOC-1182 ISSN 1011–4289, VIENNA, 2000,
Program Jaminan Mutu Operasi dan Perawatan Reaktor Kartini, Dok. No. PJM OPRK/APB-04, 2012.
Peraturan Kepala BAPETEN No.4 Tahun 2013 Tentang Proteksi Radiasi dan Keselamatan Radiasi Dalam Pemnafaatan Tenaga Nuklir.
Perka Kepala BAPETEN No. 4 Tahun 2010 Tentang Sistem Manajemen Fasilias dan Aktivitas.
Published
2016-06-30
How to Cite
Widarto, W., Atmoko, I., & Wijaya, G. (2016). Quality Management System Program of in Vitro/in Vivo Test Facility of Boron Neutron Capture Therapy at Kartini Research Reactor. Indonesian Journal of Physics and Nuclear Applications, 1(2), 108-115. https://doi.org/10.24246/ijpna.v1i2.108-115
Issue
Section
Articles

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Indonesian Journal of Physics and Nuclear Applications is licensed under a Creative Commons Attribution 4.0 International License.