Boron Neutron Capture Therapy (BNCT) using Compact Neutron generator

Authors

  • Anggraeni Dwi Susilowati Post-graduate of Physics FMIPA - Gadjah Mada University Yogyakarta
  • Kusminarto Kusminarto Post-graduate of Physics FMIPA - Gadjah Mada University Yogyakarta
  • Yohannes Sardjono Center for Accelerator Science and Technology, National Nuclear Energy Agency

DOI:

https://doi.org/10.24246/ijpna.v1i2.73-80

Keywords:

collimator, BNCT, CNG, MCNP 5

Abstract

Boron Neutron Capture Therapy (BNCT) must be appropriate with five criteria from IAEA. These criteria in order to prevent neutron beam output harm the patient. It can be by using Collimator of neutron source Compact Neutron Generator (CNG) and Monte Carlo simulation method with N particles 5 .CNG is developed by deuteriumtritium reaction (DT) and deuterium-deuterium (DD) reaction. The manufacture result of the collimator is obtained epithermal neutron flux value of 1.69e-9 n/cm^2s  for D-T reaction and 8e6 n/cm^2s for D-D reaction, ratio of epithermal and thermal is 1.95e-13 Gy cm^2/n for D-T reaction and for D-D reaction, ratio of fast neutron component is 1.69e-13 Gy cm^2/n for D-T reaction and for D-D reaction, ratio of gamma component is 1.18e-13 Gy cm^2/nfor D-T reaction and for D-D reaction. The Latest reaction is current ratio 0.649 for D-T reaction and 0.46 for D-D reaction.

Downloads

Download data is not yet available.

References

Anonim 3. Globocan. 2012. Estimated Cancer Incidence, Mortality and Prevalence Worldwide in 2012. International Agency for Research of Cancer (IARC).

Anonim 4. International Agency for Research on cancer. 2013. Latest world cancer statistics. Global cancer burden rises to 14.1 million new cases in 2012: Marked increase in breast cancers must be addressed. World Head Organization.

Anonim 5. International Atomic Energy Agency. 2012. Neutron Generators For Analytical Purposes. Vienna, Austria. ISBN 978-92-0-125110-7

Anonim 6. 2000. Table of Nuclides and Cross Section Plotter, Korea Atomic Energy Research Institute (KAERI). Taejon. Republic of Korea.

Fantidis, J.G. 2013. Optimised BNCT facility based on a compact D-D neutron generator. International Journal of Radiation Research Volume 11, No 4. Springer.

Fantidis, Jacob. 2012. Fast and Thermal Neutron Radiographies Based on a Compact Neutron Generator. International Journal of Radiation Research Springer.

Downloads

Published

2016-06-30

How to Cite

Susilowati, A. D., Kusminarto, K., & Sardjono, Y. (2016). Boron Neutron Capture Therapy (BNCT) using Compact Neutron generator. Indonesian Journal of Physics and Nuclear Applications, 1(2), 73–80. https://doi.org/10.24246/ijpna.v1i2.73-80

Issue

Section