A Design of Boron Neutron Capture Therapy for Cancer Treatment in Indonesia
Keywords:
liver, Lung carcinoma, Boron Neutron Capture Therapy, Compact DT Neutron generator
Abstract
Boron Neutron Capture Therapy (BNCT) is an advanced form of radiotherapy technique that is potentially superior to all conventional techniques for cancer treatment, as it is targeted at killing individual cancerous cells with minimal damage to surrounding healthy cells. After decades of development, BNCT has reached clinical-trial stages in several countries, mainly for treating challenging cancers such as malignant brain tumors. The Indonesian consortium of BNCT already developed of the design BNCT for many cases of type cancers using many neutron sources. The main objective of the Indonesian consortium BNCT are the development of BNCT technology package which consists of a non nuclear reactor neutron source based on cyclotron and compact neutron generator technique, advanced boron-carrying pharmaceutical, and user-friendly treatment platform with automatic operation and feedback system as well as commercialization of the BNCT though franchised network of BNCT clinics worldwide. The Indonesian consortium BNCT will offering to participate in Boron carrier pharmaceuticals development and testing, development of cyclotron and compact neutron generators and provision of neutrons from the 100 kW Kartini Research Reactor to guide and to validate compact neutron generator development. Studies were carried out to design a collimator which results in epithermal neutron beam for Boron Neutron Capture Therapy (BNCT) at the Kartini Research Reactor by means of Monte Carlo N-Particle 5 (MCNP5) codes. Reactor within 100 kW of output thermal power was used as the neutron source. The design criteria were based on the IAEA’s recommendation. All materials used were varied in size, according to the value of mean free path for each. Monte Carlo simulations indicated that by using 5 cm thick of Ni as collimator wall, 60 cm thick of Al as moderator, 15 cm thick of 60Ni as filter, 1,5 cm thick of Bi as "-ray shielding, 3 cm thick of 6Li2CO3-polyethylene as beam delimiter, with 3-5 cm varied aperture size, epithermal neutron beam with minimum flux of 7,8 x 108 n.cm-2.s-1, maximum fast neutron and "-ray components of, respectively, 1,9 x 10-13 Gy.cm2.n-1 and 1,8 x 10-13 Gy.cm2.n-1, maximum thermal neutron per epithermal neutron ratio of 0,009, and beam minimum directionality of 0,72, could be produced. The beam did not fully pass the IAEA’s criteria, since the epithermal neutron flux was still below the recommended value, 1,0 x 109 n.cm-2.s-1. Nonetheless, it was still usable with epithermal neutron flux exceeded 5 x 108 n.cm-2.s-1. When this collimator was surrounded by 8 cm thick of graphite, the characteristics of the beam became better that it passed all IAEA’s criteria with epithermal neutron flux up to 1,7 x 109 n.cm-2.s-1. it is still feasible for BNCT in vivo experiment and study of many cases cancer type i.e.; liver and lung curcinoma. In this case, thermal neutron produced by model of Collimated Thermal Column Kartini Research Nuclear Reactor, Yogyakarta. Sodium boroncaptate (BSH) was used as in this research. BSH had effected in liver for radiation quality factor as 0.8 in health tissue and 2.5 in cancer tissue. Modelling organ and source used liver organ who contain of cancer tissue and research reactor. Variation of boron concentration was 20, 25, 30, 35, 40, 45, and 47 $g/g cancer. Output of MCNP calculation were neutron scattering dose, gamma ray dose and neutron flux from reactor. Given the advantages of low density owned by lungs, hence BNCT is a solid option that can be utilized to eradicate the cell cancer in lungs. Modelling organ and neutron source for lung carcinoma was used Compact Neutron Generator (CNG) by deuterium-tritium which was used is boronophenylalanine (BPA). The concentration of boron-10 compound was varied in the study; i.e. the variations were 20; 25; 30; 35; 40 and 45 μg.g-1 cancer tissues. Ideally, the primary dose which is solemnly expected to contribute in the therapy is alpha dose, but the secondary dose; i.e. neutron scattering dose, proton dose and gamma dose that are caused due to the interaction of thermal neutron with the spectra of tissue can not be simply omitted. Thus, the desired output of MCNPX; i.e. tally, were thermal and epithermal neutron flux, neutron and photon dose. The liver study variation of boron concentration result dose rate to every variation were0,042; 0,050; 0,058; 0,067; 0,074; 0,082; 0,085 Gy/sec. Irradiation time who need to every concentration were 1194,687 sec (19 min 54 sec);999,645 sec (16 min 39 sec); 858,746 sec (14 min 19 sec); 743,810 sec (12 min 24 sec); 675,156 sec (11 min 15 sec); 608,480 sec (10 min 8 sec); 585,807sec (9 min 45 sec). The lung carcinoma study variations of boron-10 concentration in tissue resulted in the dose rate of each variables respectively were 0.003145, 0.003657, 0.00359, 0.00385, 0.00438 and 0.00476 Gy.sec-1 . The irradiated time needed for therapy for each variables respectively were 375.34, 357.55, 287.58, 284.95, 237.84 and 219.84 minutes.Downloads
Download data is not yet available.
References
World Health Organization. (2012).Statistic Health. French. 2012
Tetsuya M, Tetsuo M, and Koji N. (2011). “Progress in Nuclear Science and Technology”. Study on Microdosimetry for Boron Neutron Capture Therapy, 2: 242, 2011.
Rorer D, A. Wambersie, G. Whitmore. (2001). Current Status of Neutron Capture Therapy. IAEA- TECDOC-1223. International Atomic Energy Agency, Vienna.
Siloam. (2013).Liver Cancer. MRCCC Siloam Hospital. Jakarta
Dwi B.S. (2013). Analysis of the Critical Organ Dose Therapy with Boron Neutron Capture Glioblastoma Therapy using MCNP5 Simulation Methods, Department of Physics, Gadjah MadaUniversity, Yogyakarta
Saverio A. (2013). Research activities in neutron report, Radiotherapy at Triga Mark II, Department of Physics University of Pavia, Mainz.
Wolfgang A. G. Sauerwein and Ray L. Moss. Requirements for Boron Neutron Capture Therapy (BNCT) at a Nuclear Research Reactor. A technical document, EUR 23830 EN, European Commission Joint Research Centre, Luxembourg, 2009
Marko Maučec. Conceptual Design of Epithermal Neutron Beam for BNCT in Thermal Column of TRIGA Reactor. Nuclear Energy in Central Europe, Ljubljana, 1998.
James Michaelson, Sameer Satija, Richard Moore, Griffin Weber, Elkan Halpern, Andrew Garland, Daniel B. Kopans, and Kevin Hughes. “Estimates of the Sizes at Which Breast Cancers Become Detectable on Mammographic and Clinical Grounds”. Journal of Women’s Imaging, 5: 3-10, 2003.
Gerard AT.(2006). A Brief Atlas of the Skeleton, Surface Anatomy and Selected Medical Images, New York: John Wiley & Sons, Inc. 978-0-471-71428-6 .
HermanC and Thomas E. (2009). Introduction to Health Physics 4th Edition, McGraw – Hill, New York.
Indonesia Nuclear Energy Regulatory Agency (BAPETEN). (2013). BAPETEN Decree No.4 on Protection and Radiation Safety in Nuclear Energy Utilization, Jakarta.
Mika Kortesniemi. (2002). Solutions for Clinical Boron Neutron Capture Implementation of Therapy. University of Helsinki, Helsinki.
Nina F. (2013). A Conceptual Design of Thermal Neutron Collimator in Column of Kartini Research Reactor for Boron Neutron Capture Therapy. Faculty of Engineering, Gadjah Mada University, Yogyakarta.
Robbins and Cortran. (2003). Phatologic Basic of Disease. Chicago, Kaunders
Thomas E.B., John T.G. and Avneet S. (2003). MCNP - A General Monte Carlo N - Particle Transport Code, Version 5. LA - UR - 03-1987. Los Alamos National Laboratory, New Mexico
Tetsuya M, Tetsuo M, and Koji N. (2011). “Progress in Nuclear Science and Technology”. Study on Microdosimetry for Boron Neutron Capture Therapy, 2: 242, 2011.
Rorer D, A. Wambersie, G. Whitmore. (2001). Current Status of Neutron Capture Therapy. IAEA- TECDOC-1223. International Atomic Energy Agency, Vienna.
Siloam. (2013).Liver Cancer. MRCCC Siloam Hospital. Jakarta
Dwi B.S. (2013). Analysis of the Critical Organ Dose Therapy with Boron Neutron Capture Glioblastoma Therapy using MCNP5 Simulation Methods, Department of Physics, Gadjah MadaUniversity, Yogyakarta
Saverio A. (2013). Research activities in neutron report, Radiotherapy at Triga Mark II, Department of Physics University of Pavia, Mainz.
Wolfgang A. G. Sauerwein and Ray L. Moss. Requirements for Boron Neutron Capture Therapy (BNCT) at a Nuclear Research Reactor. A technical document, EUR 23830 EN, European Commission Joint Research Centre, Luxembourg, 2009
Marko Maučec. Conceptual Design of Epithermal Neutron Beam for BNCT in Thermal Column of TRIGA Reactor. Nuclear Energy in Central Europe, Ljubljana, 1998.
James Michaelson, Sameer Satija, Richard Moore, Griffin Weber, Elkan Halpern, Andrew Garland, Daniel B. Kopans, and Kevin Hughes. “Estimates of the Sizes at Which Breast Cancers Become Detectable on Mammographic and Clinical Grounds”. Journal of Women’s Imaging, 5: 3-10, 2003.
Gerard AT.(2006). A Brief Atlas of the Skeleton, Surface Anatomy and Selected Medical Images, New York: John Wiley & Sons, Inc. 978-0-471-71428-6 .
HermanC and Thomas E. (2009). Introduction to Health Physics 4th Edition, McGraw – Hill, New York.
Indonesia Nuclear Energy Regulatory Agency (BAPETEN). (2013). BAPETEN Decree No.4 on Protection and Radiation Safety in Nuclear Energy Utilization, Jakarta.
Mika Kortesniemi. (2002). Solutions for Clinical Boron Neutron Capture Implementation of Therapy. University of Helsinki, Helsinki.
Nina F. (2013). A Conceptual Design of Thermal Neutron Collimator in Column of Kartini Research Reactor for Boron Neutron Capture Therapy. Faculty of Engineering, Gadjah Mada University, Yogyakarta.
Robbins and Cortran. (2003). Phatologic Basic of Disease. Chicago, Kaunders
Thomas E.B., John T.G. and Avneet S. (2003). MCNP - A General Monte Carlo N - Particle Transport Code, Version 5. LA - UR - 03-1987. Los Alamos National Laboratory, New Mexico
Published
2016-02-28
How to Cite
Sardjono, Y., Widodo, S., Irhas, I., & Tantawy, H. (2016). A Design of Boron Neutron Capture Therapy for Cancer Treatment in Indonesia. Indonesian Journal of Physics and Nuclear Applications, 1(1), 1-13. https://doi.org/10.24246/ijpna.v1i1.1-13
Issue
Section
Articles

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Indonesian Journal of Physics and Nuclear Applications is licensed under a Creative Commons Attribution 4.0 International License.